| Property type | Residential property |
|---|---|
| Challenge | Leak located on external water supply pipework near the side access route |
| Solution | Safe scan, targeted excavation, pipe repair and reinstatement |
| Survey date | 29 July 2026 |
| Result | Leak repaired, retested and external meter confirmed static |
The Challenge
A residential property reported a suspected leak on the water supply pipework. Previous tracing had indicated a likely escape near the side access route, but the pipework was concealed below hardstanding.
Before excavation, the area required careful utility scanning. Power and radio services were identified, so the works needed controlled access, safe excavation and a verified repair before reinstatement.
Key Challenges
- Concealed supply pipework beneath hardstanding
- Power and radio services identified before excavation
- Leaking galvanised steel pipework exposed
- Repair needed to be verified by retesting
- Poor pipe condition created future leakage risk
The Solution
A targeted approach combined utility scanning, controlled excavation, pipe exposure, repair, retesting and reinstatement.
Utility scanning: A CAT and Genny survey was completed before excavation. Power and radio services were identified in the affected area.
Targeted excavation: Excavation was carried out at the side of the property where the previous tracer gas location had indicated the likely escape.
Pipe repair: The excavation exposed a leaking galvanised steel pipe. A repair was made to the water supply pipework while on site.
Verification and reinstatement: The pipework was retested, protected with sand, backfilled with MOT, reconcreted and the external meter confirmed static.
The Results
The investigation confirmed a leaking galvanised steel water supply pipe. Following repair and retesting, no further escape of water was present and the external meter was static.
- CAT and Genny scanning identified power and radio services
- Targeted excavation exposed the leaking galvanised steel pipe
- The water supply pipework was repaired while on site
- Retesting confirmed no further escape of water was present
- Pipework was protected, backfilled and reconcreted
- The external water meter was static after the repair
Why SOS Leak Detection?
This project demonstrates the value of combining precise leak location, safe excavation controls, on-site repair and verification before reinstatement.
-
Safe excavation planning
CAT and Genny scanning identified utilities before groundworks. -
Targeted access
Excavation was focused on the indicated leak area. -
Confirmed defect
A leaking galvanised steel supply pipe was exposed. -
End-to-end delivery
Repair, protection, backfill and reconcreting were managed together. -
Future-risk advice
Poor pipe condition was highlighted and replacement recommended.
Contact Your Leak Detection Specialists Today
"*" indicates required fields